The stack is settled before the board is ordered. Wearable PCB design for manufacturing at NexPCB chooses among a flex board, a rigid-flex board, and a flex board with a stiffener. A length that does not bend can still be flex. A soft length beside a stiffener is not a third structure.
The length that bends in use is one reason to use flex. A length that does not bend can be rigid, and it can also be flex when the stack, the assembly, or the interconnect is the reason. Rigid-flex joins a rigid length and a flex length in one board. A flex board with a stiffener is a flex board plus stiffener. It is not rigid-flex, and a soft length beside a harder length is not the definition of either one. The design file names which structure this build is using before the outline is treated as finished.
The materials and the stack are chosen together. Layer count, the substrate, and the cover are part of how a length bends. Bend also depends on the thickness, the copper, the radius, the direction, and whether the bend is static or repeated. Those are written before the board is ordered when the bend is part of this build. A bend added after the stack is fixed is reviewed as a stack change. A bend is not called passed without the radius, the angle, and the cycle count that build used.
Keeping parts, solder joints, and vias off a repeated-bend zone that the design names is a direction for that zone. A via in that zone is not, by itself, the place the board opens first. Parts sit on the straight length when the design puts the repeated bend on the other length. The arched length in the photograph carries traces only. The parts sit on the straight end, on the thicker stiffener. Green solder mask does not say which length is rigid and which is flex. The placement file and the stack file name the same line between those lengths.
| Length | Structure | What has to be true first |
|---|---|---|
| Bends in use | Flex, rigid-flex, or flex plus a stiffener, chosen for that length | Thickness, material, copper, radius, direction, and whether the bend is static or repeated |
| Does not bend | Rigid, or flex when the stack or the interconnect is the reason | Flex on this length is not automatically the wrong structure |
| Both in one product | Rigid-flex, or flex plus a stiffener. Those are different structures | The line between them is drawn before fabrication |
A rigid board forced into a repeated bend is the wrong structure for that length when the stack cannot take the bend. Flex on a length that does not bend is not automatically the wrong structure.
After the stack and the bend are settled, conduction after bending is a bend-endurance question. Temperature cycling and a drop do not replace that check. This build runs the check its specification names. A stack that looks right on the drawing has not shown that the bent length still conducts. Without the radius, the angle, and the cycle count, the bend is not called passed.
Layer count, substrate, and cover are part of the bend. Thickness, copper, radius, direction, and whether the bend is static or repeated are the rest. They are settled before the board is ordered when this build bends.
On the straight length, when the design names a repeated-bend zone and keeps parts, solder joints, and vias off it. A via in that zone is not, by itself, the first place the board opens.
Bring the length that has to bend, the length that stays straight, and the stack you expect: layers, substrate, and cover. Mark where the parts sit relative to that line. If a bend test is already named, bring the condition. Start at our project inquiry form.